4040 Seawater Desalination Membrane

1. Higher flux of produced water.

2. Highly efficient desalination performance.

3. Compact module design.

4. Energy saving and environmental protection.

5. High strength corrosion resistant materials.

6. Simple maintenance and management.

7.Wide range of applications.


Product Details

The membrane element developed by our company is suitable for marine and land installation. It is characterized by high pressure resistance (up to 6.9Mpa), low operating cost, good desalination performance and stable desalination effect. Drinking water can be obtained from seawater under the condition of high recovery rate.


4040 Seawater Desalination Membrane


Main application:

 membrane element is suitable for seawater desalination, high concentration brackish water desalination, power plant boiler make-up water and other industrial water treatment, can also be used for wastewater reuse, food and drugs and other high-value-added substances such as the concentration of recycling and many other fields. Desalination, high concentration brackish water desalination, industrial water treatment, wastewater reuse.


Parameters:

SW1-4040 Membrane Basic Performance Specification

Performances

Test condition

Conditions of use

Membrane type

Polyamide composite film

Test pressure

800psi(5.5Mpa)

Maximum operating pressure

1000psi

(6.9Mpa)

Average desalination rate

99.5%

Test temperature

25℃

Maximum inlet flow rate

16gpm(3.6m3/h)

Average transmittance GPD(m3/d)

1000(4.0)

Test concentration (NaCl)

10000ppm

Inlet water temperature

5~45℃

Effective membrane area ft2(m2)

73(7)

Test PH

6.5~7

Maximum influent SDI

5

Recovery rate of single membrane element

8%

Test time

After 30 minutes

Free chlorine concentration in feed water

0.1ppm



Cleaning PH range

1~14

Maximum allowable pressure drop of a single membrane element

20psi(0.14Mpa)

 

SW3-8040 Membrane Basic Performance Specification

Performances

Test condition

Conditions of use

Membrane type

Polyamide laminated membrane

Test pressure

800psi

(5.5Mpa)

Maximum operating pressure

1000psi

(6.9Mpa)

Average desalination rate

99.7%

Test temperature

25℃

Maximum inlet flow rate

70gpm(15.9m3/h)

Average transmittance GPD(m3/d)

6000(22.7)

Test concentration (NaCl)

10000ppm

Inlet water temperature

5~45℃

Effective membrane area ft2(m2)

370(34)

Test PH

6.5~7

Maximum influent SDI

5

Recovery rate of single membrane element

8%

Test time

30 minutes later

Free chlorine concentration in feed water

0.1ppm

Membrane type


Cleaning PH range

1~14

Maximum allowable pressure drop of a single membrane element

20psi(0.14Mpa)